2 Way Slip-In Cartridge Valves
Series C10 D*C
C10 UK.INDD CM 14.11.14
A
B
X
G
Characteristics / Ordering Code
The 2/2 way seat valves series C10 D*C are equipped
with an inductive switch to monitor the closed position.
The poppet has a 60/40 area ratio (AA = 0.6 AC, AB =
0.4 AC) and is capable for flow in both directions.
The safety overlap of the poppet avoids opening of
the valve before the signal of the inductive switch has
changed.
For sizes NG80 and NG100 a proximity switch vertical to
the poppet is used.
Features
• German trade association certificate, No. 00 077 for
NG16 to NG63 with cover 101
• Cover to mount a directional control valve (on the side)
for cover 123
• Cavity and mounting pattern acc. to ISO 7368
• Monitored closed position
• Inductive switch CE conform
• Optional poppet sealing
• 8 sizes NG16 up to NG100
Ordering code
2/2 way
valve
Seal
Code Seal
omit NBR
V FPM
Hydrau-
lically
operated
Code Nominal size
16 NG16
25 NG25
32 NG32
40 NG40
50 NG50
63 NG63
80 NG80
100 NG100
Nominal
size
Poppet
shape
Design
series
Inductive
monitoring
1)
Cover
Slip-in
cartridge
1)
German trade association certificate 00 077 only for NG16 to NG63 with cover 101.
2)
The DC valve is not included in the delivery.
Spring
Code Orifice
00 Plug
99 Without orifice, open
Cavity and
mounting
pattern
DIN ISO 7368
Poppet
seal
Code Poppet seal
omit
X425
Only with spring
code S and U
Code Spring
L Opening pressure 0.1 bar
N Opening pressure 0.5 bar
S Opening pressure 1.6 bar
U Opening pressure 4.0 bar
Orifice
Code Cover
101 without pilot valve interface
123
2)
with pilot valve interface
1
2
3
4
C D10 C E
0
00
Orifices (see 'Accessories')
B
A
C
Z1
X
YZ2
1 2
3
5
4
T
P
B
T
A
P
B
A
G
Code Design Series
Cover 101
E NG16-NG63
G NG80-NG100
Cover 123
F NG16-NG100
Cover 101
Cover 123
Position control
"00" poppet
always
closed
C10 DFC
C10 DEC
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-88
C10 UK.INDD CM 14.11.14
2 Way Slip-In Cartridge Valves
Series C10 D*C
Characteristic curve measured with HLP46 at 50 °C.
General
Size NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
Interface 2 way slip-in cartridge valves ISO 7368
Mounting position unrestricted
Operation Hydraulic
Ambient temperature [C°] -20...+60
MTTF
D
value [years] 150
Weight [kg] 1.5 2.7 4.3 7.4 12 23 53 89
Hydraulic
Max. operating pressure
[bar] 350
, connection A, B, X
Nominal flow p 5 bar [l/min] 230 400 800 1250 1625 3400 5000 7500
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [C°] -20...+70 (NBR: -25...+70)
Viscosity, permitted
recommended
[cSt] / [mm²/s]
[cSt] / [mm²/s]
20...400
30...80
Filtration ISO 4406 (1999); 18/16/13
Control volume at max. stroke [cm³] 2.03 6.45 12.21 20.32 39.40 94.56 950 1300
Control surface (surface C = 100 %) A/B [%] approx. 60 / 40 related on surface C
Opening pressure
flow direction B—>A
flow direction A—>B
[bar]
[bar]
Spring: L = 0.25; N = 1.25; S = 4.0; U = 10.0
Spring: L = 0.16; N = 0.85; S = 2.7; U = 6.6
Electrical (Inductive switch)
See position control
Technical data
Technical Data / Characteristic Curve
p/Q performance curve
(without spring and poppet seal, C-chamber unloaded)
Accessories
Orifice thread Ø
Recommended orifice diameter
Depending on function, plugs must be used (code00).
1)
Orifice thread in mm, thread in NPT.
Cover Orifice NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
101
1)
Nr.: 1 1/16 Ø0.8 1/16 Ø1.2 1/16 Ø1.5 1/8 Ø2.0 1/8 Ø2.5 1/8 Ø3.0 1/8 1/8
123
1)
No: 1, 2, 3, 4 M5 M6 M6 M6 M8 M8 1/8 1/8
Cover Orifice NG16 NG25 NG32 NG40 NG50 NG63 NG80 NG100
101
1
Ø 0.8 Ø 1.2 Ø 1.5 Ø 2.0 Ø 2.5 Ø 3.0 Ø 3.0 Ø 3.0
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-89
2 Way Slip-In Cartridge Valves
Series C10 D*C
C10 UK.INDD CM 14.11.14
Dimensions
Attention!
The switch may only be adjusted by the valve manufacturer. The exchange of individual modules is not permitted.
Seal and bolt kits
Cavity and mounting pattern acc. to ISO 7368
Dimensions C10D*C101
NG16 to NG63 with plug M12x1
1)
NG80 to NG100 without plug M12x1
2)
NG H h h2 b1 b2 d1 d2 t
+0.1
16 130 36 28 65 99.5 32 25 56
25 135 45 32.5 85 109.5 45 34 72
32 140 50 32 102 118 60 45 85
40 150 60 40 125 130 75 55 105
50 160 70 45 140 137 90 68 122
63 175 85 55 180 157 120 90 155
80 195 105 80 250 119 145 110 205
100 210 120 89 300 144 180 135 245
1)
Delivery includes plug M12x1 (order no.: 5004109).
2)
Please order plug M12x1 separately.
Nominal size 16 25 32 40 50 63 80 100
Seal kit FPM
SK-C10D-
C10E160V
SK-C10D-
C10E250V
SK-C10D-
C10E320V
SK-C10D-
C10E400V
SK-C10D-
C10E500V
SK-C10D-
C10E630V
SK-C10D-
C10E800V
SK-C10D-
C10E1000V
NBR
SK-C10D-
C10E160
SK-C10D-
C10E250
SK-C10D-
C10E320
SK-C10D-
C10E400
SK-C10D-
C10E500
SK-C10D-
C10E630
SK-C10D-
C10E800
SK-C10D-
C10E1000
Bolt kit
[ISO 4762-12.9]
BK414
4x M8x40
BK391
4x M12x50
BK415
4x M16x55
BK416
4x M20x70
BK527
4x M20x80
BK418
4x M30x100
BK419
8x M24x120
BK420
8x M30x140
Recommended torque [Nm] 31.8 108 264 517 517 1775 890 1775
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-90
C10 UK.INDD CM 14.11.14
2 Way Slip-In Cartridge Valves
Series C10 D*C
t2
H
Ød1
h1
Ød2
3,5
b1
3,5
b2
h2
Z2 Z1XY
P
A
B
T
h3
b3
1)
Delivery includes plug M12x1 (order no.: 5004109).
Dimensions
Attention!
The switch may only be adjusted by the valve manufacturer. The exchange of individual modules is not permitted.
Seal and bolt kits
Cavity and mounting pattern acc. to ISO 7368
Dimensions C10D*C123
NG16 to NG50 with plug M12x1.
1)
Pilot valve interface NG06.
NG H h1 h2 h3 b1 b2 b3 d1 d2 t2
16 170 85 76 72 65 99.5 15.5 31 25 56
25 170 85 70 72 85 109.5 15.5 45 34 72
32 170 85 56 72 102 118 15.5 60 45 85
40 170 85 50 72 125 130 15.5 75 55 105
50 170 85 60 72 140 137 15.5 90 68 122
Nominal size 16 25 32 40 50
Seal kit FPM SK-C10D-C12E160V SK-C10D-C12E250V SK-C10D-C12E320V SK-C10D-C12E400V SK-C10D-C12E500V
NBR SK-C10D-C12E160N SK-C10D-C12E250N SK-C10D-C12E320N SK-C10D-C12E400N SK-C10D-C12E500N
Bolt kit
[ISO 4762-12.9]
BK533
4x M8x90
BK532
4x M12x90
BK526
4x M16x80
BK527
4x M20x80
BK534
4x M20x90
Recommended torque
± 15 %
[Nm] 42,2 144 354 692 692
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-91
2 Way Slip-In Cartridge Valves
Series C10 D*C
C10 UK.INDD CM 14.11.14
Øb1
Y
Z2 Z1
3.5
Lifting eye bolt
M12-DIN 580
Lifting thread for
disassembley
NG80: M24
NG100: M30
3.5
Ht2
Ød2
Ød1
h1
h2
b2
T
T
B
P
A
h3
b3
Dimensions
Attention!
The switch may only be adjusted by the valve manufacturer. The exchange of individual modules is not permitted.
Cavity and mounting pattern acc. to ISO 7368
NG80 to NG100 without plug M12x1
2)
Pilot valve interface NG10.
NG H h1 h2 h3 b1 b2 b3 d1 d2 t2
63 195 110 75 91 180 157 21.5 120 90 155
80 212.5 120 94 91 250 119 21.5 145 110 205
100 212.5 120 85 91 300 144 21.5 180 135 245
Nominal size 63 80 100
Seal kit FPM SK-C10D-C12E630V SK-C10D-C12E800V SK-C10D-C12E1000V
NBR SK-C10D-C12E630N SK-C10D-C12E800N SK-C10D-C12E1000N
Bolt kit
[ISO 4762-12.9]
BK536
4x M30x120
BK535
8x M24x130
BK531
8x M30x150
Recommended torque
± 15 %
[Nm] 2380 1190 2390
Seal and bolt kits
Lifting eye bolt
M12-DIN 580
Ød2
Ød1
3.5
3.5
b2
b3
H
h3
h1
h2
t2
Z2 Z1
b1
T
A
P
B
4
Dimensions C10D*C123
NG63 with plug M12x1.
1)
Pilot valve interface NG10.
1)
Delivery includes plug M12x1 (order no.: 5004109).
2)
Please order plug M12x1 separately.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-92
C10 UK.INDD CM 14.11.14
2 Way Slip-In Cartridge Valves
Series C10 D*CPosition Control
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C] 0...+50
Supply voltage U
S
/ ripple [V] 18...42 / 10 %
Current consumption without load [mA] 30
Max. output current per channel, ohmic [mA] 400
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V] 1.1
Max. output drop at 0.4 A [V] 1.6
EMC EN50081-1 / EN50082-2
Max. tolerance ambient field strength [A/m] <1200
Min. distance to next AC solenoid [m] >0.1
Interface M12x1
Wiring min. [mm²] 5 x 0.25 braid shield recommended
Wiring length max. [m] 50 recommended
Electrical characteristics of position control as per IEC 61076-2-101 (M12x1), NG16 to NG63
M12 pin assignment
1 + U
S
18...42 V
2 Out B: normally open
3 0V
4 Out A: normally closed
5 Earth ground
Extract from the German trade association certificate
Fachausschuss Maschinenbau,
Hebezeuge, Hütten- und
Walzwerksanlagen
Prüf- und Zertifizierungsstelle
im BG-PRÜFZERT
Hauptverband der gewerblichen
Berufsgenossenschaften
Name und Anschrift Parker Hannifin GmbH
des Bescheinigungsinhabers: Hydraulic Controls Division
(Auftraggeber) Gutenbergstr. 38 - 40, D- 41564 Kaarst
Name und Anschrift Parker Hannifin GmbH
des Herstellers: Hydraulic Controls Division
Gutenbergstr. 38 - 40, D- 41564 Kaarst
Zeichen des Auftraggebers: Zeichen der Prüf- und Zertifizierungsstelle:
MHHW 612.1:612.28-UB Gb/bt
Produktbezeichnung: 2/2- Wegesitzventil mit Überwachung
Einbauventil nach DIN 24342 (entspricht DIN ISO 7368)
Typ: C10 DEC 101.....
Das geprüfte Baumuster entspricht den einschlägigen Bestimmungen der EG-Maschinenrichtline 2006/42/EG.
Bescheinigungs-Nummer
00 077
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
8-93
2 Way Slip-In Cartridge Valves
Series C10 D*C
C10 UK.INDD CM 14.11.14
Position Control
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Ambient temperature [°C] 0...+50
Supply voltage U
S
/ ripple [V] 10...30 / 10 %
Current consumption without load [mA] 10
Max. output current per channel, ohmic [mA] 200
Min. output load per channel, ohmic [kOhm] 100
Max. output drop at 0.2 A [V] 2
EMC EN61000-6-4 / EN61000-6-2
Min. distance to next AC solenoid [m] >0.1
Interface M12x1
Wiring min. [mm²] 3 x 0.14 braid shield recommended
Wiring length max. [m] 50 recommended
Electrical characteristics of position control M12x1 as per IEC 61076-2-101, NG80 to NG100
M12 pin assignment
1 + U
S
10...30 V
2 Out A: not connected
3 0V
4 Out A: normally closed
Definition
Start position monitored:
The switching point of the inductive switch is within the
overlap of the poppet.
After the signal of the inductive switch has changed, the